{"id":7044,"date":"2022-06-15T03:01:00","date_gmt":"2022-06-15T03:01:00","guid":{"rendered":"https:\/\/kt0gfz7z5i.onrocket.site\/?p=7044"},"modified":"2026-11-21T09:16:47","modified_gmt":"2026-11-21T09:16:47","slug":"distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis","status":"publish","type":"post","link":"https:\/\/www.pvb.com\/cs\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/","title":{"rendered":"Nebezpe\u010d\u00ed vzniku elektrick\u00e9ho oblouku a po\u017e\u00e1ru u distribuovan\u00e9 PV elektr\u00e1rny DC \u2013 anal\u00fdza rizik aplika\u010dn\u00edho sc\u00e9n\u00e1\u0159e"},"content":{"rendered":"<p><strong>Nebezpe\u010d\u00ed po\u017e\u00e1ru<\/strong><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/www.beny.com\/wp-content\/uploads\/2022\/06\/image.png\" alt=\"obr\u00e1zek\" class=\"wp-image-18264\"\/><\/figure><\/div>\n\n\n<p>V posledn\u00edch letech doch\u00e1z\u00ed k \u010dast\u00fdm po\u017e\u00e1r\u016fm elektr\u00e1ren PV. Tyto ud\u00e1losti zp\u016fsobuj\u00ed nejen ztr\u00e1ty majetku a p\u0159\u00edjm\u016f z v\u00fdroby elekt\u0159iny, ale tak\u00e9 po\u0161kozen\u00ed budov a zran\u011bn\u00ed osob; po\u017e\u00e1r se m\u016f\u017ee roz\u0161\u00ed\u0159it i do okol\u00ed a zp\u016fsobit \u0159adu n\u00e1sledn\u00fdch \u0161kod.<\/p>\n\n\n\n<p>Obloukov\u00fd v\u00fdboj DC je nej\u010dast\u011bj\u0161\u00ed poruchou v elektr\u00e1rn\u00e1ch PV. K obloukov\u00e9mu v\u00fdboji m\u016f\u017ee doj\u00edt v d\u016fsledku uvoln\u011bn\u00e9ho kontaktu, st\u00e1rnut\u00ed za\u0159\u00edzen\u00ed, poru\u0161en\u00ed izolace nebo nedostate\u010dn\u00e9ho uzemn\u011bn\u00ed. Nebezpe\u010d\u00ed obloukov\u00e9ho v\u00fdboje DC je nav\u00edc mnohem v\u011bt\u0161\u00ed ne\u017e u obloukov\u00e9ho v\u00fdboje AC, proto\u017ee oblouk DC nem\u00e1 pr\u016fchod nulou. Jakmile vznikne, ho\u0159\u00ed nep\u0159etr\u017eit\u011b, obt\u00ed\u017en\u011b se has\u00ed a m\u016f\u017ee snadno zp\u016fsobit po\u017e\u00e1r. Podle statistik jsou obloukov\u00e9 v\u00fdboje DC p\u0159\u00ed\u010dinou v\u00edce ne\u017e poloviny po\u017e\u00e1r\u016f elektr\u00e1ren PV. S rostouc\u00edmi rozm\u011bry modul\u016f PV se zvy\u0161uje v\u00fdkon i proud na stran\u011b syst\u00e9mu DC. Podle Jouleova z\u00e1kona Q=I\u00b2Rt se p\u0159i zdvojn\u00e1soben\u00ed proudu tepeln\u00fd \u00fa\u010dinek v m\u00edst\u011b zkratu zv\u00fd\u0161\u00ed \u010dty\u0159n\u00e1sobn\u011b a v\u00fdrazn\u011b roste tak\u00e9 riziko po\u017e\u00e1ru.<\/p>\n\n\n\n<p><strong>Klasifikace obloukov\u00fdch v\u00fdboj\u016f DC<\/strong><\/p>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/www.beny.com\/wp-content\/uploads\/2022\/06\/image-1.png\" alt=\"obr\u00e1zek 1\" class=\"wp-image-18265\"\/><\/figure><\/div>\n\n\n<p><\/p>\n\n\n\n<p>Na rozd\u00edl od tradi\u010dn\u00edch elektrick\u00fdch za\u0159\u00edzen\u00ed nemaj\u00ed moduly PV ani jejich kabel\u00e1\u017e vlastn\u00ed kryt, kter\u00fd by zadr\u017eel oblouky a jiskry zp\u016fsoben\u00e9 poruchami komponent\u016f a kabel\u00e1\u017ee, p\u0159i\u010dem\u017e mnoho instalac\u00ed PV m\u016f\u017ee pracovat p\u0159i b\u011b\u017en\u00fdch nap\u011bt\u00edch DC, kter\u00e1 udr\u017euj\u00ed oblouky DC.<\/p>\n\n\n\n<p>V instalac\u00edch PV se vyskytuj\u00ed t\u0159i hlavn\u00ed typy elektrick\u00fdch oblouk\u016f:<\/p>\n\n\n\n<p>\u2014 S\u00e9riov\u00e9 oblouky mohou vznikat v d\u016fsledku nespr\u00e1vn\u00e9ho zapojen\u00ed nebo p\u0159eru\u0161en\u00ed s\u00e9riov\u00e9ho veden\u00ed<\/p>\n\n\n\n<p>\u2014 Paraleln\u00ed oblouky mohou vznikat v d\u016fsledku \u010d\u00e1ste\u010dn\u00fdch zkrat\u016f mezi sousedn\u00edmi vodi\u010di s r\u016fzn\u00fdmi potenci\u00e1ly<\/p>\n\n\n\n<p>\u2014 Zemn\u00ed oblouky zp\u016fsoben\u00e9 poruchou izolace<\/p>\n\n\n\n<p><strong>S\u00e9riov\u00fd oblouk<\/strong><\/p>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/www.beny.com\/wp-content\/uploads\/2022\/06\/image-2.png\" alt=\"obr\u00e1zek 2\" class=\"wp-image-18266\"\/><\/figure><\/div>\n\n\n<p><\/p>\n\n\n\n<p>S\u00e9riov\u00fd oblouk, zn\u00e1m\u00fd tak\u00e9 jako ta\u017een\u00fd oblouk, obvykle vznik\u00e1 p\u0159i \u0161patn\u00e9m kontaktu kabelov\u00fdch konektor\u016f mezi komponenty nebo p\u0159i nekvalitn\u00edm spojen\u00ed kabel\u016f string\u016f se slu\u010dovac\u00edmi sk\u0159\u00edn\u011bmi \u010di st\u0159\u00edda\u010di. Vzhledem k velk\u00e9mu po\u010dtu s\u00e9riov\u00fdch konektor\u016f v elektr\u00e1rn\u011b PV obsahuje st\u0159e\u0161n\u00ed elektr\u00e1rna 1MW PV a\u017e 2000 p\u00e1r\u016f konektor\u016f. U takov\u00e9ho mno\u017estv\u00ed p\u00e1r\u016f je obt\u00ed\u017en\u00e9 zajistit, aby byly v\u0161echny konektory kvalitn\u00ed. Tyto probl\u00e9my vedou ke \u0161patn\u00e9mu kontaktu a vzniku oblouk\u016f DC.<\/p>\n\n\n\n<p>V sou\u010dasnosti m\u00e1 n\u011bkolik st\u0159\u00edda\u010d\u016f integrovanou funkci ochrany proti elektrick\u00e9mu oblouku, tato ochrana m\u00e1 v\u0161ak dva z\u00e1sadn\u00ed nedostatky: Zaprv\u00e9, pokud dojde k poru\u0161e obloukem v jednom stringu, vypne se cel\u00fd st\u0159\u00edda\u010d, co\u017e vede k velk\u00e9 ztr\u00e1t\u011b v\u00fdroby elekt\u0159iny. Zadruh\u00e9, bez funkce lokalizace poruchy obloukem nemohou pracovn\u00edci provozu a \u00fadr\u017eby v\u010das a p\u0159esn\u011b zjistit m\u00edsto oblouku, tak\u017ee tento probl\u00e9m z\u016fst\u00e1v\u00e1 v podstat\u011b nevy\u0159e\u0161en\u00fd. Jedin\u00fdm technick\u00fdm opat\u0159en\u00edm, kter\u00e9 mohou pou\u017e\u00edt, je obnoven\u00ed provozu st\u0159\u00edda\u010de. Z tohoto pohledu nem\u016f\u017ee integrovan\u00e1 funkce ochrany proti ta\u017een\u00e9mu oblouku ve st\u0159\u00edda\u010di skute\u010dn\u011b \u00fa\u010dinn\u011b \u0159e\u0161it poruchy zp\u016fsoben\u00e9 ta\u017een\u00fdm obloukem.<\/p>\n\n\n\n<p><strong>Paraleln\u00ed oblouk<\/strong><\/p>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/www.beny.com\/wp-content\/uploads\/2022\/06\/image-3.png\" alt=\"obr\u00e1zek 3\" class=\"wp-image-18267\"\/><\/figure><\/div>\n\n\n<p><\/p>\n\n\n\n<p>Paraleln\u00ed oblouky vznikaj\u00ed p\u0159edev\u0161\u00edm zkratem mezi kladn\u00fdm a z\u00e1porn\u00fdm vodi\u010dem zp\u016fsoben\u00fdm po\u0161kozen\u00edm veden\u00ed nebo zkratem mezi kabely string\u016f. Pokud jsou kabely string\u016f mechanicky stla\u010deny nebo od\u0159eny, m\u016f\u017ee mezi kladn\u00fdm a z\u00e1porn\u00fdm p\u00f3lem nebo mezi r\u016fzn\u00fdmi stringy vzniknout oblouk, tedy porucha paraleln\u00edm obloukem. K paraleln\u00edm oblouk\u016fm m\u016f\u017ee v\u00e9st i dal\u0161\u00ed situace: pokud nejsou s\u00e9riov\u00e9 oblouky v syst\u00e9mu v\u010das odstran\u011bny, jejich teplo prop\u00e1l\u00ed izolaci kabel\u016f a vzniknou paraleln\u00ed oblouky.<\/p>\n\n\n\n<p>P\u0159i vzniku paraleln\u00edho oblouku mezi hlavn\u00edmi vodi\u010di pole komponent\u016f m\u016f\u017ee oblouk z\u00edskat dostatek energie, a proto se obt\u00ed\u017en\u011bji zh\u00e1\u0161uje, co\u017e m\u016f\u017ee v\u00e9st k rozs\u00e1hl\u00e9mu po\u017e\u00e1ru. S\u00e9riov\u00fd poruchov\u00fd oblouk lze uhasit odpojen\u00edm sb\u011brnice DC nebo p\u0159\u00edslu\u0161n\u00e9ho stringu syst\u00e9mu PV&nbsp;, paraleln\u00ed poruchov\u00fd oblouk v\u0161ak uhasit nelze a m\u016f\u017ee dokonce zp\u016fsobit pr\u016fchod v\u011bt\u0161\u00edho proudu dr\u00e1hou oblouku, \u010d\u00edm\u017e se oblouk je\u0161t\u011b zes\u00edl\u00ed.<\/p>\n\n\n\n<p>V sou\u010dasnosti nedok\u00e1\u017ee funkce ochrany proti oblouku integrovan\u00e1 ve st\u0159\u00edda\u010di detekovat paraleln\u00ed oblouky ani zemn\u00ed oblouky&nbsp;, p\u0159esto\u017ee destruktivn\u00ed \u00fa\u010dinky paraleln\u00edch oblouk\u016f b\u00fdvaj\u00ed desetkr\u00e1t v\u011bt\u0161\u00ed ne\u017e u s\u00e9riov\u00fdch oblouk\u016f a p\u0159edstavuj\u00ed je\u0161t\u011b v\u011bt\u0161\u00ed bezpe\u010dnostn\u00ed riziko.<\/p>\n\n\n\n<p><strong>Zemn\u00ed oblouk<\/strong><\/p>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/www.beny.com\/wp-content\/uploads\/2022\/06\/image-4.png\" alt=\"obr\u00e1zek 4\" class=\"wp-image-18268\"\/><\/figure><\/div>\n\n\n<p><\/p>\n\n\n\n<p>St\u00e1rnut\u00ed a po\u0161kozen\u00ed komponent\u016f nebo mechanick\u00e9 po\u0161kozen\u00ed zp\u016fsobuj\u00ed zemn\u00ed v\u00fdboje. Pokud jsou komponenty polo\u017eeny naplocho na st\u0159echu z barevn\u00fdch ocelov\u00fdch plech\u016f, m\u016f\u017ee doch\u00e1zet k zemn\u00edm oblouk\u016fm nebo svodov\u00fdm proud\u016fm. Tuto poruchu nen\u00ed snadn\u00e9 zjistit, zejm\u00e9na za de\u0161tiv\u00e9ho po\u010das\u00ed. V sou\u010dasnosti se \u0159e\u0161\u00ed vypnut\u00edm st\u0159\u00edda\u010de a vy\u010dk\u00e1n\u00edm, a\u017e zemina vyschne, ne\u017e se st\u0159\u00edda\u010d znovu spust\u00ed. Tento postup nedok\u00e1\u017ee \u00fa\u010dinn\u011b odstranit rizika a zvy\u0161uje nebezpe\u010d\u00ed \u00farazu elektrick\u00fdm proudem.<\/p>\n\n\n\n<p><strong>Vysok\u00e9 nap\u011bt\u00ed DC<\/strong><\/p>\n\n\n\n<p>V PV&nbsp;elektr\u00e1rn\u011b jsou moduly PV&nbsp;zapojeny do s\u00e9rie a vytv\u00e1\u0159ej\u00ed DC vysokonap\u011b\u0165ov\u00fd obvod, kter\u00fd obvykle dosahuje p\u0159ibli\u017en\u011b 1000V. I kdy\u017e je syst\u00e9m vypnut\u00fd, v matici modul\u016f PV&nbsp;je st\u00e1le p\u0159\u00edtomno DC vysok\u00e9 nap\u011bt\u00ed p\u0159ibli\u017en\u011b 1000 volt\u016f. Zejm\u00e9na u st\u0159e\u0161n\u00edch elektr\u00e1ren PV&nbsp;je p\u0159i po\u017e\u00e1ru v elektr\u00e1rn\u00e1ch PV&nbsp;a budov\u00e1ch obt\u00ed\u017en\u00e9 bezpe\u010dn\u011b zasahovat; p\u0159i b\u011b\u017en\u00e9m provozu a \u00fadr\u017eb\u011b elektr\u00e1rny nebo \u00fadr\u017eb\u011b nemovitosti jsou riziku \u00farazu elektrick\u00fdm proudem vystaveni tak\u00e9 provozovatel\u00e9 a inspekto\u0159i.&nbsp;<\/p>\n\n\n\n<p><strong>Anal\u00fdza rizik podle sc\u00e9n\u00e1\u0159\u016f<\/strong><\/p>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/www.beny.com\/wp-content\/uploads\/2022\/06\/image-6.png\" alt=\"obr\u00e1zek 6\" class=\"wp-image-18270\"\/><\/figure><\/div>\n\n\n<p><\/p>\n\n\n\n<p><strong>Vl\u00e1dn\u00ed budovy,&nbsp;\u0161koly, nemocnice, obytn\u00e9 st\u0159echy<\/strong><\/p>\n\n\n\n<p>1. Kontrola oblasti.&nbsp;Pomoc\u00ed dron\u016f nelze skenovat komponenty a odhalovat odchylky ani v\u010das zjistit nebezpe\u010d\u00ed;<\/p>\n\n\n\n<p>2. Vysok\u00e1 hustota obyvatelstva.&nbsp;V poli komponent\u016f doch\u00e1z\u00ed ke svodov\u00fdm proud\u016fm, co\u017e p\u0159edstavuje vysok\u00e9 riziko \u00farazu elektrick\u00fdm proudem;<\/p>\n\n\n\n<p>3. Omezen\u00e9 mo\u017enosti z\u00e1sahu. V p\u0159\u00edpad\u011b po\u017e\u00e1ru nebo jin\u00e9 nouzov\u00e9 situace nelze vypnout vysok\u00e9 nap\u011bt\u00ed stringu, co\u017e br\u00e1n\u00ed z\u00e1chrann\u00fdm prac\u00edm;<\/p>\n\n\n\n<p>4. Dopad na ve\u0159ejn\u00e9 m\u00edn\u011bn\u00ed. Pokud&nbsp;dojde k nehod\u011b, m\u016f\u017ee m\u00edt v\u00fdrazn\u00fd dopad na ve\u0159ejn\u00e9 m\u00edn\u011bn\u00ed<\/p>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/www.beny.com\/wp-content\/uploads\/2022\/06\/image-7.png\" alt=\"obr\u00e1zek 7\" class=\"wp-image-18271\"\/><\/figure><\/div>\n\n\n<p><\/p>\n\n\n\n<p><strong>R\u016fzn\u00e9 st\u0159echy z barevn\u00fdch ocelov\u00fdch plech\u016f<\/strong><\/p>\n\n\n\n<p>1. Obt\u00ed\u017en\u00e1 kontrola.&nbsp;Kontrola st\u0159ech z barevn\u00fdch ocelov\u00fdch plech\u016f je nepraktick\u00e1 a nebezpe\u010d\u00ed souvisej\u00edc\u00ed s elektrick\u00fdm obloukem&nbsp;nelze v\u010das odhalit;<\/p>\n\n\n\n<p>2. Omezen\u00e9 mo\u017enosti z\u00e1sahu. V p\u0159\u00edpad\u011b po\u017e\u00e1ru nebo jin\u00e9 nouzov\u00e9 situace nelze vypnout vysok\u00e9 nap\u011bt\u00ed stringu, co\u017e br\u00e1n\u00ed z\u00e1chrann\u00fdm prac\u00edm;<\/p>\n\n\n\n<p>3. K\u0159ehk\u00e1 st\u0159echa.&nbsp;Jiskra oblouku DC m\u016f\u017ee snadno prop\u00e1lit barevn\u00fd ocelov\u00fd plech a proniknout do prostoru pod st\u0159echou, zp\u016fsobit po\u017e\u00e1r a \u0161kody na majetku<\/p>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/www.beny.com\/wp-content\/uploads\/2022\/06\/image-8.png\" alt=\"obr\u00e1zek 8\" class=\"wp-image-18272\"\/><\/figure><\/div>\n\n\n<p><\/p>\n\n\n\n<p><strong>D\u00e1lnice, \u0159eky a dal\u0161\u00ed oblasti<\/strong><\/p>\n\n\n\n<p>1. Rizika v okoln\u00edm prost\u0159ed\u00ed.&nbsp;Nahodil\u00e9 jiskry z nedopalk\u016f cigaret a komponent\u016f mohou snadno zap\u00e1lit vegetaci pod nimi;<\/p>\n\n\n\n<p>2. Obt\u00ed\u017en\u00e1 kontrola.&nbsp;Dlouh\u00e9 a \u00fazk\u00e9 oblasti se obt\u00ed\u017en\u011b kontroluj\u00ed, provoz a \u00fadr\u017eba jsou n\u00e1ro\u010dn\u00e9 a nebezpe\u010d\u00ed nelze v\u010das odhalit;<\/p>\n\n\n\n<p>3. Obt\u00ed\u017en\u00fd z\u00e1sah.&nbsp;V odlehl\u00fdch oblastech daleko od m\u011bst je z\u00e1sah p\u0159i po\u017e\u00e1ru \u010di jin\u00e9 nehod\u011b obt\u00ed\u017en\u00fd;<\/p>\n\n\n\n<p>4. N\u00e1sledn\u00e1 nehoda.&nbsp;Pokud vozidlo nebo jin\u00e1 nehoda po\u0161kod\u00ed komponenty, nelze vysok\u00e9 nap\u011bt\u00ed stringu v\u010das vypnout, co\u017e m\u016f\u017ee v\u00e9st k z\u00e1va\u017en\u00e9 n\u00e1sledn\u00e9 nehod\u011b.<\/p>\n\n\n\n<p><strong>Vnitrost\u00e1tn\u00ed&nbsp;z\u00e1kony a p\u0159edpisy<\/strong><\/p>\n\n\n\n<p><strong>USA:<\/strong><\/p>\n\n\n\n<p>Podle nejnov\u011bj\u0161\u00edho vyd\u00e1n\u00ed dokumentu National Electrical Code NEC2020:<\/p>\n\n\n\n<p>Jako hranice se stanov\u00ed vzd\u00e1lenost 305 mm od pole PV; mimo tuto hranici mus\u00ed nap\u011bt\u00ed do 30S od aktivace spou\u0161t\u011bc\u00edho za\u0159\u00edzen\u00ed klesnout pod 30V. Uvnit\u0159 hranice mus\u00ed b\u00fdt instalov\u00e1n \u201esyst\u00e9m \u0159\u00edzen\u00ed rizika PV&nbsp;\u201c nebo mus\u00ed nap\u011bt\u00ed do 30S od aktivace spou\u0161t\u011bc\u00edho za\u0159\u00edzen\u00ed klesnout pod 80V.<\/p>\n\n\n\n<p><strong>Kanada:<\/strong><\/p>\n\n\n\n<p>Podle vyd\u00e1n\u00ed Canadian Electrical Code z roku 2021:<\/p>\n\n\n\n<p>Pokud nap\u011bt\u00ed na stran\u011b DC syst\u00e9mu PV&nbsp;p\u0159ekro\u010d\u00ed 80V, m\u011blo by b\u00fdt instalov\u00e1no za\u0159\u00edzen\u00ed pro p\u0159eru\u0161en\u00ed poruchov\u00e9ho oblouku nebo jin\u00e9 rovnocenn\u00e9 za\u0159\u00edzen\u00ed.<\/p>\n\n\n\n<p>Pokud je syst\u00e9m PV&nbsp;instalov\u00e1n v budov\u011b nebo na n\u00ed, m\u011blo by b\u00fdt instalov\u00e1no za\u0159\u00edzen\u00ed pro rychl\u00e9 vypnut\u00ed. Ve vzd\u00e1lenosti 1 metru od modulu PV mus\u00ed po aktivaci za\u0159\u00edzen\u00ed pro rychl\u00e9 vypnut\u00ed nap\u011bt\u00ed do 30S klesnout pod 30V.<\/p>\n\n\n\n<p><strong>N\u011bmecko:<\/strong><\/p>\n\n\n\n<p>Podle n\u011bmeck\u00e9 normy&nbsp;VDE-AR-E 2100-712:<\/p>\n\n\n\n<p>V syst\u00e9mu PV&nbsp;mus\u00ed b\u00fdt p\u0159i vypnut\u00e9m st\u0159\u00edda\u010di nebo v\u00fdpadku s\u00edt\u011b nap\u011bt\u00ed DC ni\u017e\u0161\u00ed ne\u017e 120V. Norma zmi\u0148uje pou\u017eit\u00ed vyp\u00ednac\u00edho&nbsp;za\u0159\u00edzen\u00ed, kter\u00e9 sn\u00ed\u017e\u00ed nap\u011bt\u00ed na stran\u011b&nbsp;DC pod 120V.<\/p>\n\n\n\n<p><strong>Austr\u00e1lie:<\/strong><\/p>\n\n\n\n<p>Podle&nbsp;\u010dl\u00e1nku&nbsp;4.3.3 nejnov\u011bj\u0161\u00ed normy AS\/NZS 5033:2021:<\/p>\n\n\n\n<p>Pokud nap\u011bt\u00ed DC p\u0159ekro\u010d\u00ed 120Vd.c, je nutn\u00e9 instalovat odpojovac\u00ed za\u0159\u00edzen\u00ed mezi modul a st\u0159\u00edda\u010d.<\/p>\n\n\n\n<p><strong>Thajsko:<\/strong><\/p>\n\n\n\n<p>Podle&nbsp;\u010dl\u00e1nku 4.3.13&nbsp;thajsk\u00e9ho p\u0159edpisu Electrical Code-Solar Rooftop Power Supply Installations&nbsp;2022:<\/p>\n\n\n\n<p>St\u0159e\u0161n\u00ed elektr\u00e1rna PV&nbsp;mus\u00ed b\u00fdt vybavena za\u0159\u00edzen\u00edm pro rychl\u00e9 vypnut\u00ed; hranice je stanovena 300mm od pole PV. Nap\u011bt\u00ed uvnit\u0159 t\u00e9to hranice se mus\u00ed do 30 sekund od aktivace za\u0159\u00edzen\u00ed sn\u00ed\u017eit pod 80V a nap\u011bt\u00ed mimo tuto hranici mus\u00ed klesnout pod 30V.<\/p>\n\n\n\n<p><strong>Vlastn\u00ed produkty PVB z v\u00fdzkumu a v\u00fdvoje<\/strong><\/p>\n\n\n\n<p>Pro po\u017e\u00e1rn\u00ed bezpe\u010dnost sol\u00e1rn\u00edch syst\u00e9m\u016f na st\u0159ech\u00e1ch a budov\u00e1ch \u0159\u00edd\u00ed za\u0159\u00edzen\u00ed pro rychl\u00e9 odpojen\u00ed na \u00farovni PVB\u00a0string\u016f a modul\u016f nap\u011bt\u00ed panel\u016f tak, aby b\u011bhem mikrosekundy kleslo na ur\u010ditou bezpe\u010dnou \u00farove\u0148. P\u0159edch\u00e1zejte nehod\u00e1m a zvy\u0161ujte bezpe\u010dnost sol\u00e1rn\u00edho syst\u00e9mu.\u00a0\u0158e\u0161en\u00ed rychl\u00e9ho odpojen\u00ed PVB jsou navr\u017eena v souladu s normami CE, TUV a UL a spl\u0148uj\u00ed n\u00e1rodn\u00ed z\u00e1kony a p\u0159edpisy, jako je Thai Electrical Code a NEC2020. Jako \u010dlen aliance Sunspec vyv\u00edj\u00ed PVB\u00a0komunikaci PLC RSDs pro \u0161ir\u0161\u00ed kompatibilitu s v\u00edce\u0159et\u011bzcov\u00fdmi st\u0159\u00edda\u010di. Prohl\u00e9dn\u011bte si produkty.<\/p>\n\n\n\n<p><strong>Z\u00e1v\u011br<\/strong><\/p>\n\n\n\n<p>V\u00fdstavba elektr\u00e1ren PV&nbsp;je v pln\u00e9m proudu a \u00fazce propojuje tis\u00edce dom\u00e1cnost\u00ed. Jak zajistit&nbsp;<strong>\u201ebezpe\u010dnost\u201c<\/strong>&nbsp;elektr\u00e1ren PV&nbsp;je t\u00e9matem, kter\u00e9mu cel\u00fd obor v\u011bnuje velkou pozornost.&nbsp;K \u00fa\u010dinn\u00e9mu \u0159e\u0161en\u00ed tohoto probl\u00e9mu mus\u00ed cel\u00fd obor spolupracovat na inovativn\u00edch \u0159e\u0161en\u00edch a pr\u016fb\u011b\u017en\u011b zdokonalovat p\u0159\u00edslu\u0161n\u00e9 normy a p\u0159edpisy, aby byly odpov\u00eddaj\u00edc\u00ed po\u017eadavky skute\u010dn\u011b uplat\u0148ov\u00e1ny p\u0159i n\u00e1sledn\u00e9 v\u00fdstavb\u011b elektr\u00e1ren.<\/p>\n\n\n\n<p>Bezpe\u010dn\u00fd, stabiln\u00ed a efektivn\u00ed provoz elektr\u00e1ren PV&nbsp;jako\u017eto d\u016fle\u017eit\u00e9 energetick\u00e9 infrastruktury je z\u00e1sadn\u00ed z\u00e1rukou hospod\u00e1\u0159sk\u00e9ho rozvoje.<\/p>","protected":false},"excerpt":{"rendered":"<p>Fire Safety Hazard In recent years, PV power station fire accidents have occurred frequently, which not only lose the power station property and power generation income, but also cause building damage and personal injury, and even spreads to the surrounding environment, resulting in a series of secondary disasters. DC arc is the most common fault [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":18378,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_eb_attr":"","footnotes":""},"categories":[49],"tags":[66],"class_list":["post-7044","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","tag-industry-news"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.1 (Yoast SEO v27.1.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Solar Safety Analysis | DC Arc Risks in PV Power Stations | PVB Energy Storage<\/title>\n<meta name=\"description\" content=\"Unlock the secrets to preventing solar power fires. Learn how DC arcs cause hazards in PV stations and the innovative solutions to mitigate risks.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.pvb.com\/cs\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/\" \/>\n<meta property=\"og:locale\" content=\"cs_CZ\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Distributed PV power station DC arc and fire \u201csafety\u201d hazard \u2013 application scenario risk analysis\" \/>\n<meta property=\"og:description\" content=\"Unlock the secrets to preventing solar power fires. Learn how DC arcs cause hazards in PV stations and the innovative solutions to mitigate risks.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.pvb.com\/cs\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/\" \/>\n<meta property=\"og:site_name\" content=\"PVB Energy Storage\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/pvbmicropowerhub\" \/>\n<meta property=\"article:published_time\" content=\"2022-06-15T03:01:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-21T09:16:47+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.pvb.com\/wp-content\/uploads\/2022\/06\/22.6.15.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"PVB Energy Storage\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@PVB_PowerVault\" \/>\n<meta name=\"twitter:site\" content=\"@PVB_PowerVault\" \/>\n<meta name=\"twitter:label1\" content=\"Napsal(a)\" \/>\n\t<meta name=\"twitter:data1\" content=\"PVB Energy Storage\" \/>\n\t<meta name=\"twitter:label2\" content=\"Odhadovan\u00e1 doba \u010dten\u00ed\" \/>\n\t<meta name=\"twitter:data2\" content=\"9 minut\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/\"},\"author\":{\"@id\":\"https:\/\/www.pvb.com\/cs\/#organization\"},\"headline\":\"Distributed PV power station DC arc and fire \u201csafety\u201d hazard \u2013 application scenario risk analysis\",\"datePublished\":\"2022-06-15T03:01:00+00:00\",\"dateModified\":\"2026-11-21T09:16:47+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/\"},\"wordCount\":1667,\"publisher\":{\"@id\":\"https:\/\/www.pvb.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.pvb.com\/wp-content\/uploads\/2022\/06\/22.6.15.webp\",\"keywords\":[\"Industry News\"],\"articleSection\":[\"News\"],\"inLanguage\":\"cs\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/\",\"url\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/\",\"name\":\"Solar Safety Analysis | DC Arc Risks in PV Power Stations | PVB Energy Storage\",\"isPartOf\":{\"@id\":\"https:\/\/www.pvb.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.pvb.com\/wp-content\/uploads\/2022\/06\/22.6.15.webp\",\"datePublished\":\"2022-06-15T03:01:00+00:00\",\"dateModified\":\"2026-11-21T09:16:47+00:00\",\"description\":\"Unlock the secrets to preventing solar power fires. Learn how DC arcs cause hazards in PV stations and the innovative solutions to mitigate risks.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#breadcrumb\"},\"inLanguage\":\"cs\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"cs\",\"@id\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#primaryimage\",\"url\":\"https:\/\/www.pvb.com\/wp-content\/uploads\/2022\/06\/22.6.15.webp\",\"contentUrl\":\"https:\/\/www.pvb.com\/wp-content\/uploads\/2022\/06\/22.6.15.webp\",\"width\":1280,\"height\":720,\"caption\":\"Fire Safety Hazard\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.pvb.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Distributed PV power station DC arc and fire \u201csafety\u201d hazard \u2013 application scenario risk analysis\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.pvb.com\/#website\",\"url\":\"https:\/\/www.pvb.com\/\",\"name\":\"PVB Energy Storage\",\"description\":\"PV Battery Solutions\",\"publisher\":{\"@id\":\"https:\/\/www.pvb.com\/#organization\"},\"alternateName\":\"PVB\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.pvb.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"cs\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.pvb.com\/#organization\",\"name\":\"PVB Energy Storage\",\"url\":\"https:\/\/www.pvb.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"cs\",\"@id\":\"https:\/\/www.pvb.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.pvb.com\/wp-content\/uploads\/2023\/10\/20251218-144542.png\",\"contentUrl\":\"https:\/\/www.pvb.com\/wp-content\/uploads\/2023\/10\/20251218-144542.png\",\"width\":826,\"height\":800,\"caption\":\"PVB Energy Storage\"},\"image\":{\"@id\":\"https:\/\/www.pvb.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/pvbmicropowerhub\",\"https:\/\/x.com\/PVB_PowerVault\"],\"alternateName\":[\"PVB\"],\"parentOrganization\":{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.beny.com\/#organization\",\"name\":\"BENY New Energy\",\"url\":\"https:\/\/www.beny.com\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.pvb.com\/#\/schema\/person\/9e2e81b5f4240256ac8618c6f5aed1d2\",\"name\":\"PVB Energy Storage\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"cs\",\"@id\":\"https:\/\/www.pvb.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/22d020bc1b45981d5477872a66ace2a1258a147e929471f93f367387d7c67855?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/22d020bc1b45981d5477872a66ace2a1258a147e929471f93f367387d7c67855?s=96&d=mm&r=g\",\"caption\":\"PVB Energy Storage\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Anal\u00fdza bezpe\u010dnosti sol\u00e1rn\u00edch syst\u00e9m\u016f | Rizika obloukov\u00fdch v\u00fdboj\u016f DC v elektr\u00e1rn\u00e1ch PV | PVB Energy Storage","description":"Odhalte, jak p\u0159edch\u00e1zet po\u017e\u00e1r\u016fm sol\u00e1rn\u00edch elektr\u00e1ren. Zjist\u011bte, jak obloukov\u00e9 v\u00fdboje DC p\u0159edstavuj\u00ed riziko v elektr\u00e1rn\u00e1ch PV a jak\u00e1 inovativn\u00ed \u0159e\u0161en\u00ed tato rizika zm\u00edr\u0148uj\u00ed.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.pvb.com\/cs\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/","og_locale":"cs_CZ","og_type":"article","og_title":"Distributed PV power station DC arc and fire \u201csafety\u201d hazard \u2013 application scenario risk analysis","og_description":"Unlock the secrets to preventing solar power fires. Learn how DC arcs cause hazards in PV stations and the innovative solutions to mitigate risks.","og_url":"https:\/\/www.pvb.com\/cs\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/","og_site_name":"PVB Energy Storage","article_publisher":"https:\/\/www.facebook.com\/pvbmicropowerhub","article_published_time":"2022-06-15T03:01:00+00:00","article_modified_time":"2026-11-21T09:16:47+00:00","og_image":[{"width":1280,"height":720,"url":"https:\/\/www.pvb.com\/wp-content\/uploads\/2022\/06\/22.6.15.webp","type":"image\/webp"}],"author":"PVB Energy Storage","twitter_card":"summary_large_image","twitter_creator":"@PVB_PowerVault","twitter_site":"@PVB_PowerVault","twitter_misc":{"Napsal(a)":"PVB Energy Storage","Odhadovan\u00e1 doba \u010dten\u00ed":"9 minut"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#article","isPartOf":{"@id":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/"},"author":{"@id":"https:\/\/www.pvb.com\/cs\/#organization"},"headline":"Distributed PV power station DC arc and fire \u201csafety\u201d hazard \u2013 application scenario risk analysis","datePublished":"2022-06-15T03:01:00+00:00","dateModified":"2026-11-21T09:16:47+00:00","mainEntityOfPage":{"@id":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/"},"wordCount":1667,"publisher":{"@id":"https:\/\/www.pvb.com\/#organization"},"image":{"@id":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#primaryimage"},"thumbnailUrl":"https:\/\/www.pvb.com\/wp-content\/uploads\/2022\/06\/22.6.15.webp","keywords":["Industry News"],"articleSection":["News"],"inLanguage":"cs"},{"@type":"WebPage","@id":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/","url":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/","name":"Anal\u00fdza bezpe\u010dnosti sol\u00e1rn\u00edch syst\u00e9m\u016f | Rizika obloukov\u00fdch v\u00fdboj\u016f DC v elektr\u00e1rn\u00e1ch PV | PVB Energy Storage","isPartOf":{"@id":"https:\/\/www.pvb.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#primaryimage"},"image":{"@id":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#primaryimage"},"thumbnailUrl":"https:\/\/www.pvb.com\/wp-content\/uploads\/2022\/06\/22.6.15.webp","datePublished":"2022-06-15T03:01:00+00:00","dateModified":"2026-11-21T09:16:47+00:00","description":"Odhalte, jak p\u0159edch\u00e1zet po\u017e\u00e1r\u016fm sol\u00e1rn\u00edch elektr\u00e1ren. Zjist\u011bte, jak obloukov\u00e9 v\u00fdboje DC p\u0159edstavuj\u00ed riziko v elektr\u00e1rn\u00e1ch PV a jak\u00e1 inovativn\u00ed \u0159e\u0161en\u00ed tato rizika zm\u00edr\u0148uj\u00ed.","breadcrumb":{"@id":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#breadcrumb"},"inLanguage":"cs","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/"]}]},{"@type":"ImageObject","inLanguage":"cs","@id":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#primaryimage","url":"https:\/\/www.pvb.com\/wp-content\/uploads\/2022\/06\/22.6.15.webp","contentUrl":"https:\/\/www.pvb.com\/wp-content\/uploads\/2022\/06\/22.6.15.webp","width":1280,"height":720,"caption":"Fire Safety Hazard"},{"@type":"BreadcrumbList","@id":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.pvb.com\/"},{"@type":"ListItem","position":2,"name":"Distributed PV power station DC arc and fire \u201csafety\u201d hazard \u2013 application scenario risk analysis"}]},{"@type":"WebSite","@id":"https:\/\/www.pvb.com\/#website","url":"https:\/\/www.pvb.com\/","name":"PVB Ukl\u00e1d\u00e1n\u00ed energie","description":"PV Bateriov\u00e1 \u0159e\u0161en\u00ed","publisher":{"@id":"https:\/\/www.pvb.com\/#organization"},"alternateName":"PVB","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.pvb.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"cs"},{"@type":"Organization","@id":"https:\/\/www.pvb.com\/#organization","name":"PVB Ukl\u00e1d\u00e1n\u00ed energie","url":"https:\/\/www.pvb.com\/","logo":{"@type":"ImageObject","inLanguage":"cs","@id":"https:\/\/www.pvb.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.pvb.com\/wp-content\/uploads\/2023\/10\/20251218-144542.png","contentUrl":"https:\/\/www.pvb.com\/wp-content\/uploads\/2023\/10\/20251218-144542.png","width":826,"height":800,"caption":"PVB Energy Storage"},"image":{"@id":"https:\/\/www.pvb.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/pvbmicropowerhub","https:\/\/x.com\/PVB_PowerVault"],"alternateName":["PVB"],"parentOrganization":{"@type":"Organization","@id":"https:\/\/www.beny.com\/#organization","name":"BENY New Energy","url":"https:\/\/www.beny.com\/"}},{"@type":"Person","@id":"https:\/\/www.pvb.com\/#\/schema\/person\/9e2e81b5f4240256ac8618c6f5aed1d2","name":"PVB Ukl\u00e1d\u00e1n\u00ed energie","image":{"@type":"ImageObject","inLanguage":"cs","@id":"https:\/\/www.pvb.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/22d020bc1b45981d5477872a66ace2a1258a147e929471f93f367387d7c67855?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/22d020bc1b45981d5477872a66ace2a1258a147e929471f93f367387d7c67855?s=96&d=mm&r=g","caption":"PVB Energy Storage"}}]}},"_links":{"self":[{"href":"https:\/\/www.pvb.com\/cs\/wp-json\/wp\/v2\/posts\/7044","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pvb.com\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pvb.com\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pvb.com\/cs\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pvb.com\/cs\/wp-json\/wp\/v2\/comments?post=7044"}],"version-history":[{"count":4,"href":"https:\/\/www.pvb.com\/cs\/wp-json\/wp\/v2\/posts\/7044\/revisions"}],"predecessor-version":[{"id":7534,"href":"https:\/\/www.pvb.com\/cs\/wp-json\/wp\/v2\/posts\/7044\/revisions\/7534"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.pvb.com\/cs\/wp-json\/wp\/v2\/media\/18378"}],"wp:attachment":[{"href":"https:\/\/www.pvb.com\/cs\/wp-json\/wp\/v2\/media?parent=7044"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pvb.com\/cs\/wp-json\/wp\/v2\/categories?post=7044"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pvb.com\/cs\/wp-json\/wp\/v2\/tags?post=7044"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}