{"id":7044,"date":"2022-06-15T03:01:00","date_gmt":"2022-06-15T03:01:00","guid":{"rendered":"https:\/\/kt0gfz7z5i.onrocket.site\/?p=7044"},"modified":"2026-11-21T09:16:47","modified_gmt":"2026-11-21T09:16:47","slug":"distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis","status":"publish","type":"post","link":"https:\/\/www.pvb.com\/no\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/","title":{"rendered":"Lysbue- og brannfare ved distribuert PV-kraftverk DC \u2013 risikoanalyse av bruksscenarioer"},"content":{"rendered":"<p><strong>Brannfare<\/strong><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/www.beny.com\/wp-content\/uploads\/2022\/06\/image.png\" alt=\"bilde\" class=\"wp-image-18264\"\/><\/figure><\/div>\n\n\n<p>De siste \u00e5rene har branner i PV-kraftverk forekommet hyppig. De f\u00f8rer ikke bare til tap av anleggsverdier og inntekter fra kraftproduksjon, men ogs\u00e5 til skader p\u00e5 bygninger og personskader. Brannene kan dessuten spre seg til omgivelsene og f\u00f8re til en rekke sekund\u00e6rskader.<\/p>\n\n\n\n<p>Lysbuer i DC er den vanligste feiltypen i PV-kraftverk. Lysbuer kan oppst\u00e5 som f\u00f8lge av l\u00f8se kontakter, aldring av utstyr, brudd i isolasjonen eller mangelfull jording. Faren ved lysbuer i DC er langt st\u00f8rre enn ved lysbuer i AC, fordi det ikke finnes noe nullgjennomgangspunkt i lysbuer i DC. N\u00e5r de f\u00f8rst oppst\u00e5r, fortsetter de \u00e5 brenne, er vanskelige \u00e5 slokke og kan lett f\u00f8re til brann. If\u00f8lge statistikken skyldes mer enn halvparten av brannene i PV&nbsp;-kraftverk lysbuer i DC. Etter hvert som st\u00f8rrelsen p\u00e5 PV&nbsp;-modulene \u00f8ker, \u00f8ker ogs\u00e5 effekten og str\u00f8mmen i systemet p\u00e5 DC-siden. If\u00f8lge Joules lov Q=I\u00b2Rt dobles str\u00f8mmen, og varmeutviklingen ved kortslutningspunktet blir fire ganger st\u00f8rre. Dermed \u00f8ker ogs\u00e5 brannfaren betydelig.<\/p>\n\n\n\n<p><strong>Klassifisering av lysbuer i DC<\/strong><\/p>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/www.beny.com\/wp-content\/uploads\/2022\/06\/image-1.png\" alt=\"bilde 1\" class=\"wp-image-18265\"\/><\/figure><\/div>\n\n\n<p><\/p>\n\n\n\n<p>I motsetning til tradisjonelt elektrisk utstyr har PV-moduler og tilh\u00f8rende kabling ikke et integrert kapslingssystem som kan begrense lysbuer og gnister for\u00e5rsaket av feil i komponenter og kabling. Samtidig kan mange PV-anlegg drives med typiske DC-spenninger som opprettholder DC-lysbuer.<\/p>\n\n\n\n<p>Det finnes tre hovedtyper lysbuer i PV-anlegg:<\/p>\n\n\n\n<p>\u2014 Serielysbuer kan skyldes feil kabling eller brudd i seriekablingen<\/p>\n\n\n\n<p>\u2014 Parallellysbuer kan skyldes delvise kortslutninger mellom tilst\u00f8tende ledninger med ulikt potensial<\/p>\n\n\n\n<p>\u2014 Jordingslysbuer&nbsp;som f\u00f8lge av isolasjonsfeil<\/p>\n\n\n\n<p><strong>Serielysbue<\/strong><\/p>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/www.beny.com\/wp-content\/uploads\/2022\/06\/image-2.png\" alt=\"bilde 2\" class=\"wp-image-18266\"\/><\/figure><\/div>\n\n\n<p><\/p>\n\n\n\n<p>Serielysbue, ogs\u00e5 kjent som trukket lysbue. Serielysbuer skyldes vanligvis d\u00e5rlig kontakt i kabelplugger mellom komponenter og d\u00e5rlig tilkobling mellom strengkabler og samlebokser eller vekselrettere. P\u00e5 grunn av det store antallet serieplugger i PV&nbsp;kraftverket finnes det 2000 par plugger i et 1MW-kraftverk p\u00e5 taket med PV. Det er vanskelig \u00e5 sikre at alle pluggene har god kvalitet n\u00e5r det er s\u00e5 mange par. Disse farene kan f\u00f8re til d\u00e5rlig kontakt og dannelse av DC-lysbuer.<\/p>\n\n\n\n<p>Enkelte vekselrettere har i dag integrert lysbuevern, men denne beskyttelsen har to store svakheter: For det f\u00f8rste vil en lysbuefeil i \u00e9n streng f\u00f8re til at hele vekselretteren kobles ut, noe som medf\u00f8rer store tap i kraftproduksjonen. For det andre kan driftspersonellet ikke finne lysbuens plassering raskt og n\u00f8yaktig uten en funksjon for lokalisering av lysbuefeil. I praksis finnes det ingen l\u00f8sning. Den eneste tekniske tilbakestillingsbeskyttelsen de kan bruke, er \u00e5 holde vekselretteren i drift. Sett fra dette perspektivet l\u00f8ser den integrerte lysbuebeskyttelsen i vekselretteren ikke problemet med lysbuefeil p\u00e5 en effektiv m\u00e5te.<\/p>\n\n\n\n<p><strong>Parallellysbue<\/strong><\/p>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/www.beny.com\/wp-content\/uploads\/2022\/06\/image-3.png\" alt=\"bilde 3\" class=\"wp-image-18267\"\/><\/figure><\/div>\n\n\n<p><\/p>\n\n\n\n<p>Parallellysbuer skyldes hovedsakelig kortslutning mellom positive og negative ledere som f\u00f8lge av skader p\u00e5 kabler, eller kortslutning mellom strengkabler. Hvis strengkabler klemmes eller slites mekanisk, kan det oppst\u00e5 lysbuer mellom de positive og negative polene eller mellom ulike strenger. Dette er en parallellysbuefeil. En annen mulig \u00e5rsak til parallellysbuer er at serielysbuer i systemet ikke h\u00e5ndteres i tide. Varmen fra serielysbuene brenner da gjennom kabelisolasjonen og f\u00f8rer til parallellysbuer.<\/p>\n\n\n\n<p>N\u00e5r en parallellysbue oppst\u00e5r mellom hovedlederne i komponentmatrisen, kan lysbuen f\u00e5 tilstrekkelig energi til at den blir vanskeligere \u00e5 slokke, noe som kan f\u00f8re til en storbrann. En serielysbuefeil kan slokkes ved \u00e5 koble fra DC-samleskinnen eller den aktuelle strengen i PV&nbsp;-systemet. En parallellysbuefeil kan derimot ikke slokkes p\u00e5 denne m\u00e5ten og kan til og med f\u00f8re til at en st\u00f8rre str\u00f8m g\u00e5r gjennom lysbuebanen, slik at lysbuen blir kraftigere.<\/p>\n\n\n\n<p>Lysbuevernet som for tiden er integrert i vekselrettere, kan ikke oppdage parallellysbuer eller jordingslysbuer. Destruksjonskraften til parallellysbuer er imidlertid ofte ti ganger st\u00f8rre enn for serielysbuer, og sikkerhetsrisikoen er enda h\u00f8yere.<\/p>\n\n\n\n<p><strong>Jordingslysbue<\/strong><\/p>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/www.beny.com\/wp-content\/uploads\/2022\/06\/image-4.png\" alt=\"bilde 4\" class=\"wp-image-18268\"\/><\/figure><\/div>\n\n\n<p><\/p>\n\n\n\n<p>Aldring og skade p\u00e5 komponenter eller mekanisk skade kan f\u00f8re til jordfeilutladning. Hvis komponentene legges flatt p\u00e5 tak med farget st\u00e5lplater, kan det oppst\u00e5 jordingslysbuer eller lekkasjestr\u00f8m. Denne typen feil er vanskelig \u00e5 oppdage, s\u00e6rlig p\u00e5 regnv\u00e6rsdager. L\u00f8sningen i dag er \u00e5 sl\u00e5 av vekselretteren og vente til bakken har t\u00f8rket f\u00f8r den startes igjen. Denne metoden fjerner ikke farene effektivt og \u00f8ker risikoen for elektrisk st\u00f8t.<\/p>\n\n\n\n<p><strong>H\u00f8yspenning i DC<\/strong><\/p>\n\n\n\n<p>I et PV&nbsp;kraftverk kobles PV&nbsp;moduler i serie for \u00e5 danne en h\u00f8yspenningskrets p\u00e5 DC, som vanligvis n\u00e5r omtrent 1000V. Selv n\u00e5r systemet er sl\u00e5tt av, er det fortsatt en h\u00f8yspenning p\u00e5 omtrent 1000 volt i PV&nbsp;modulmatrisen p\u00e5 DC. Ved brann i PV&nbsp;kraftverk&nbsp;og bygninger, s\u00e6rlig i kraftverk med PV&nbsp;p\u00e5 taket, er det vanskelig \u00e5 utf\u00f8re redningsarbeid p\u00e5 en trygg m\u00e5te. Under rutinemessig drift og vedlikehold av kraftverket eller vedlikehold av eiendommen risikerer ogs\u00e5 operat\u00f8rer og inspekt\u00f8rer elektrisk st\u00f8t.&nbsp;<\/p>\n\n\n\n<p><strong>Risikoanalyse for ulike bruksscenarioer<\/strong><\/p>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/www.beny.com\/wp-content\/uploads\/2022\/06\/image-6.png\" alt=\"bilde 6\" class=\"wp-image-18270\"\/><\/figure><\/div>\n\n\n<p><\/p>\n\n\n\n<p><strong>Offentlige bygg,&nbsp;skoler, sykehus, boligtak<\/strong><\/p>\n\n\n\n<p>1. Regional kontroll.&nbsp;Det er umulig \u00e5 bruke droner til \u00e5 skanne komponentene for avvik, og farer kan ikke oppdages i tide;<\/p>\n\n\n\n<p>2. H\u00f8y befolkningstetthet.&nbsp;Det er lekkasje i komponentmatrisen, noe som gir h\u00f8y risiko for elektrisk st\u00f8t;<\/p>\n\n\n\n<p>3. Begrensede redningsmuligheter. Ved n\u00f8dsituasjoner som brann kan h\u00f8yspenningen i strengen ikke kobles ut, noe som hindrer redningsarbeidet;<\/p>\n\n\n\n<p>4. Omd\u00f8mmevirkning. Hvis en ulykke&nbsp;inntreffer, kan den f\u00e5 store konsekvenser for omd\u00f8mmet<\/p>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/www.beny.com\/wp-content\/uploads\/2022\/06\/image-7.png\" alt=\"bilde 7\" class=\"wp-image-18271\"\/><\/figure><\/div>\n\n\n<p><\/p>\n\n\n\n<p><strong>Ulike tak med farget st\u00e5lplatetekking<\/strong><\/p>\n\n\n\n<p>1. Vanskelig \u00e5 inspisere.&nbsp;Tak med farget st\u00e5lplatetekking er vanskelige \u00e5 inspisere, og lysbuefarer kan&nbsp;ikke oppdages i tide;<\/p>\n\n\n\n<p>2. Begrensede redningsmuligheter. Ved n\u00f8dsituasjoner som brann kan h\u00f8yspenningen i strengen ikke kobles ut, noe som hindrer redningsarbeidet;<\/p>\n\n\n\n<p>3. Skj\u00f8re tak.&nbsp;Lysbuegnister i DC kan lett brenne gjennom st\u00e5lplaten med farget overflate og n\u00e5 rommet under, noe som kan f\u00f8re til brann og materielle skader<\/p>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/www.beny.com\/wp-content\/uploads\/2022\/06\/image-8.png\" alt=\"bilde 8\" class=\"wp-image-18272\"\/><\/figure><\/div>\n\n\n<p><\/p>\n\n\n\n<p><strong>Motorveier, elver og andre omr\u00e5der<\/strong><\/p>\n\n\n\n<p>1. Milj\u00f8risiko.&nbsp;Sporadiske lysbuegnister fra sigarettstumper og komponenter kan lett antenne ugresset nedenfor;<\/p>\n\n\n\n<p>2. Vanskelig \u00e5 inspisere.&nbsp;Det er upraktisk \u00e5 inspisere lange og smale omr\u00e5der, drifts- og vedlikeholdsarbeidet er krevende, og farer kan ikke oppdages i tide;<\/p>\n\n\n\n<p>3. Vanskelig \u00e5 utf\u00f8re redningsarbeid.&nbsp;N\u00e5r en ulykke som brann skjer langt fra byomr\u00e5der, er det vanskelig \u00e5 komme til unnsetning;<\/p>\n\n\n\n<p>4. Sekund\u00e6rulykker.&nbsp;Hvis kj\u00f8ret\u00f8y eller andre ulykker skader komponentene, kan h\u00f8yspenningen i strengen ikke kobles ut i tide, noe som lett kan f\u00f8re til en alvorlig sekund\u00e6rulykke.<\/p>\n\n\n\n<p><strong>Nasjonale&nbsp;lover og forskrifter<\/strong><\/p>\n\n\n\n<p><strong>USA:<\/strong><\/p>\n\n\n\n<p>I henhold til den nyeste utgaven av National Electrical Code, NEC2020:<\/p>\n\n\n\n<p>Sett en avstand p\u00e5 305mm fra PV&nbsp;-matrisen som grense. Utenfor grensen skal spenningen falle under 30V innen 30S etter at utl\u00f8serenheten er aktivert. Innenfor grensen kreves det et \u00absystem for kontroll av PV&nbsp;-fare\u00bb, eller at spenningen reduseres til under 80V innen 30S etter at utl\u00f8serenheten er aktivert.<\/p>\n\n\n\n<p><strong>Canada:<\/strong><\/p>\n\n\n\n<p>I henhold til 2021-utgaven av Canadian Electrical Code:<\/p>\n\n\n\n<p>N\u00e5r spenningen p\u00e5 DC-siden av PV&nbsp;systemet er h\u00f8yere enn 80V, b\u00f8r det installeres en lysbuefeilbryter eller tilsvarende utstyr.<\/p>\n\n\n\n<p>N\u00e5r PV&nbsp;systemet installeres i eller p\u00e5 bygningen, b\u00f8r det installeres en hurtigavstengningsenhet. 1 meter fra PV&nbsp;modulen skal spenningen reduseres til under 30V innen 30S etter at hurtigavstengningsenheten er aktivert.<\/p>\n\n\n\n<p><strong>Tyskland:<\/strong><\/p>\n\n\n\n<p>I henhold til den tyske standarden VDE-AR-E 2100-712:<\/p>\n\n\n\n<p>I PV&nbsp;systemet m\u00e5 DC-spenningen v\u00e6re lavere enn 120V dersom vekselretteren er sl\u00e5tt av eller str\u00f8mnettet svikter. Bruk av en avstengningsenhet nevnes for \u00e5 redusere spenningen p\u00e5 DC-siden til under 120V.<\/p>\n\n\n\n<p><strong>Australia:<\/strong><\/p>\n\n\n\n<p>I henhold til&nbsp;avsnitt&nbsp;4.3.3 i den nyeste standarden AS\/NZS 5033:2021:<\/p>\n\n\n\n<p>N\u00e5r DC-spenningen er h\u00f8yere enn 120Vd.c, m\u00e5 det installeres en frakoblingsenhet mellom modulen og vekselretteren.<\/p>\n\n\n\n<p><strong>Thailand:<\/strong><\/p>\n\n\n\n<p>I henhold til&nbsp;avsnitt 4.3.13&nbsp;i Thai Electrical Code-Solar Rooftop Power Supply Installations&nbsp;2022:<\/p>\n\n\n\n<p>Det kreves at PV&nbsp;kraftverket p\u00e5 taket er utstyrt med en hurtigavstengningsenhet, med en avstand p\u00e5 maksimalt 300mm fra PV&nbsp;matrisen. Spenningen innenfor grenseomr\u00e5det skal reduseres til under 80V innen 30 sekunder etter at enheten er aktivert, og spenningen utenfor grenseomr\u00e5det skal reduseres til under 30V.<\/p>\n\n\n\n<p><strong>PVB egenutviklede produkter<\/strong><\/p>\n\n\n\n<p>For brannsikkerhet p\u00e5 solcelleanlegg p\u00e5 tak og i bygninger reduserer PVB hurtigavstengningsenheter p\u00e5 streng- og modulniv\u00e5 panelspenningen til et visst sikkert niv\u00e5 p\u00e5 mikrosekunder. Dette forebygger ulykker og \u00f8ker sikkerheten til solkraftanlegget. PVB hurtigavstengningsl\u00f8sninger er utformet i henhold til CE-, TUV- og UL-standarder og er i samsvar med nasjonale lover og forskrifter, som Thai Electrical Code og NEC2020. Som medlem av Sunspec-alliansen utvikler PVB PLC-kommunikasjon RSDs for bredere kompatibilitet med flere strenginvertere. Se produktene n\u00e5.<\/p>\n\n\n\n<p><strong>Avslutning<\/strong><\/p>\n\n\n\n<p>Utbyggingen av PV&nbsp;kraftverk&nbsp;er i full gang, og de er n\u00e5 tett knyttet til tusenvis av husholdninger. Hvordan sikre&nbsp;<strong>\u00absikkerheten\u00bb<\/strong>&nbsp;til PV&nbsp;kraftverk&nbsp;f\u00e5r stor oppmerksomhet i hele bransjen.&nbsp;For \u00e5 l\u00f8se dette problemet effektivt m\u00e5 hele bransjen samarbeide om \u00e5 utvikle innovative l\u00f8sninger og kontinuerlig forbedre relevante standarder og forskrifter, slik at kravene faktisk blir fulgt opp i den videre utbyggingen av kraftverk.<\/p>\n\n\n\n<p>Som viktig energiinfrastruktur er sikker, stabil og effektiv drift av PV&nbsp;kraftverk&nbsp;en viktig forutsetning for \u00f8konomisk utvikling.<\/p>","protected":false},"excerpt":{"rendered":"<p>Fire Safety Hazard In recent years, PV power station fire accidents have occurred frequently, which not only lose the power station property and power generation income, but also cause building damage and personal injury, and even spreads to the surrounding environment, resulting in a series of secondary disasters. DC arc is the most common fault [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":18378,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_eb_attr":"","footnotes":""},"categories":[49],"tags":[66],"class_list":["post-7044","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","tag-industry-news"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.1 (Yoast SEO v27.1.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Solar Safety Analysis | DC Arc Risks in PV Power Stations | PVB Energy Storage<\/title>\n<meta name=\"description\" content=\"Unlock the secrets to preventing solar power fires. Learn how DC arcs cause hazards in PV stations and the innovative solutions to mitigate risks.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.pvb.com\/no\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/\" \/>\n<meta property=\"og:locale\" content=\"nb_NO\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Distributed PV power station DC arc and fire \u201csafety\u201d hazard \u2013 application scenario risk analysis\" \/>\n<meta property=\"og:description\" content=\"Unlock the secrets to preventing solar power fires. Learn how DC arcs cause hazards in PV stations and the innovative solutions to mitigate risks.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.pvb.com\/no\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/\" \/>\n<meta property=\"og:site_name\" content=\"PVB Energy Storage\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/pvbmicropowerhub\" \/>\n<meta property=\"article:published_time\" content=\"2022-06-15T03:01:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-21T09:16:47+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.pvb.com\/wp-content\/uploads\/2022\/06\/22.6.15.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"PVB Energy Storage\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@PVB_PowerVault\" \/>\n<meta name=\"twitter:site\" content=\"@PVB_PowerVault\" \/>\n<meta name=\"twitter:label1\" content=\"Skrevet av\" \/>\n\t<meta name=\"twitter:data1\" content=\"PVB Energy Storage\" \/>\n\t<meta name=\"twitter:label2\" content=\"Ansl. lesetid\" \/>\n\t<meta name=\"twitter:data2\" content=\"9 minutter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/\"},\"author\":{\"@id\":\"https:\/\/www.pvb.com\/no\/#organization\"},\"headline\":\"Distributed PV power station DC arc and fire \u201csafety\u201d hazard \u2013 application scenario risk analysis\",\"datePublished\":\"2022-06-15T03:01:00+00:00\",\"dateModified\":\"2026-11-21T09:16:47+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/\"},\"wordCount\":1667,\"publisher\":{\"@id\":\"https:\/\/www.pvb.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.pvb.com\/wp-content\/uploads\/2022\/06\/22.6.15.webp\",\"keywords\":[\"Industry News\"],\"articleSection\":[\"News\"],\"inLanguage\":\"nb-NO\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/\",\"url\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/\",\"name\":\"Solar Safety Analysis | DC Arc Risks in PV Power Stations | PVB Energy Storage\",\"isPartOf\":{\"@id\":\"https:\/\/www.pvb.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.pvb.com\/wp-content\/uploads\/2022\/06\/22.6.15.webp\",\"datePublished\":\"2022-06-15T03:01:00+00:00\",\"dateModified\":\"2026-11-21T09:16:47+00:00\",\"description\":\"Unlock the secrets to preventing solar power fires. Learn how DC arcs cause hazards in PV stations and the innovative solutions to mitigate risks.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#breadcrumb\"},\"inLanguage\":\"nb-NO\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nb-NO\",\"@id\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#primaryimage\",\"url\":\"https:\/\/www.pvb.com\/wp-content\/uploads\/2022\/06\/22.6.15.webp\",\"contentUrl\":\"https:\/\/www.pvb.com\/wp-content\/uploads\/2022\/06\/22.6.15.webp\",\"width\":1280,\"height\":720,\"caption\":\"Fire Safety Hazard\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.pvb.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Distributed PV power station DC arc and fire \u201csafety\u201d hazard \u2013 application scenario risk analysis\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.pvb.com\/#website\",\"url\":\"https:\/\/www.pvb.com\/\",\"name\":\"PVB Energy Storage\",\"description\":\"PV Battery Solutions\",\"publisher\":{\"@id\":\"https:\/\/www.pvb.com\/#organization\"},\"alternateName\":\"PVB\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.pvb.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nb-NO\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.pvb.com\/#organization\",\"name\":\"PVB Energy Storage\",\"url\":\"https:\/\/www.pvb.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"nb-NO\",\"@id\":\"https:\/\/www.pvb.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.pvb.com\/wp-content\/uploads\/2023\/10\/20251218-144542.png\",\"contentUrl\":\"https:\/\/www.pvb.com\/wp-content\/uploads\/2023\/10\/20251218-144542.png\",\"width\":826,\"height\":800,\"caption\":\"PVB Energy Storage\"},\"image\":{\"@id\":\"https:\/\/www.pvb.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/pvbmicropowerhub\",\"https:\/\/x.com\/PVB_PowerVault\"],\"alternateName\":[\"PVB\"],\"parentOrganization\":{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.beny.com\/#organization\",\"name\":\"BENY New Energy\",\"url\":\"https:\/\/www.beny.com\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.pvb.com\/#\/schema\/person\/9e2e81b5f4240256ac8618c6f5aed1d2\",\"name\":\"PVB Energy Storage\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"nb-NO\",\"@id\":\"https:\/\/www.pvb.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/22d020bc1b45981d5477872a66ace2a1258a147e929471f93f367387d7c67855?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/22d020bc1b45981d5477872a66ace2a1258a147e929471f93f367387d7c67855?s=96&d=mm&r=g\",\"caption\":\"PVB Energy Storage\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Analyse av solenergisikkerhet | DC Lysbuerisiko i PV kraftverk | PVB energilagring","description":"L\u00e6r hvordan branner i solkraftanlegg kan forebygges. Finn ut hvordan lysbuer i DC skaper farer i PV-anlegg, og bli kjent med innovative l\u00f8sninger for \u00e5 redusere risikoen.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.pvb.com\/no\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/","og_locale":"nb_NO","og_type":"article","og_title":"Distributed PV power station DC arc and fire \u201csafety\u201d hazard \u2013 application scenario risk analysis","og_description":"Unlock the secrets to preventing solar power fires. Learn how DC arcs cause hazards in PV stations and the innovative solutions to mitigate risks.","og_url":"https:\/\/www.pvb.com\/no\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/","og_site_name":"PVB Energy Storage","article_publisher":"https:\/\/www.facebook.com\/pvbmicropowerhub","article_published_time":"2022-06-15T03:01:00+00:00","article_modified_time":"2026-11-21T09:16:47+00:00","og_image":[{"width":1280,"height":720,"url":"https:\/\/www.pvb.com\/wp-content\/uploads\/2022\/06\/22.6.15.webp","type":"image\/webp"}],"author":"PVB Energy Storage","twitter_card":"summary_large_image","twitter_creator":"@PVB_PowerVault","twitter_site":"@PVB_PowerVault","twitter_misc":{"Skrevet av":"PVB Energy Storage","Ansl. lesetid":"9 minutter"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#article","isPartOf":{"@id":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/"},"author":{"@id":"https:\/\/www.pvb.com\/no\/#organization"},"headline":"Distributed PV power station DC arc and fire \u201csafety\u201d hazard \u2013 application scenario risk analysis","datePublished":"2022-06-15T03:01:00+00:00","dateModified":"2026-11-21T09:16:47+00:00","mainEntityOfPage":{"@id":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/"},"wordCount":1667,"publisher":{"@id":"https:\/\/www.pvb.com\/#organization"},"image":{"@id":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#primaryimage"},"thumbnailUrl":"https:\/\/www.pvb.com\/wp-content\/uploads\/2022\/06\/22.6.15.webp","keywords":["Industry News"],"articleSection":["News"],"inLanguage":"nb-NO"},{"@type":"WebPage","@id":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/","url":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/","name":"Analyse av solenergisikkerhet | DC Lysbuerisiko i PV kraftverk | PVB energilagring","isPartOf":{"@id":"https:\/\/www.pvb.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#primaryimage"},"image":{"@id":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#primaryimage"},"thumbnailUrl":"https:\/\/www.pvb.com\/wp-content\/uploads\/2022\/06\/22.6.15.webp","datePublished":"2022-06-15T03:01:00+00:00","dateModified":"2026-11-21T09:16:47+00:00","description":"L\u00e6r hvordan branner i solkraftanlegg kan forebygges. Finn ut hvordan lysbuer i DC skaper farer i PV-anlegg, og bli kjent med innovative l\u00f8sninger for \u00e5 redusere risikoen.","breadcrumb":{"@id":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#breadcrumb"},"inLanguage":"nb-NO","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/"]}]},{"@type":"ImageObject","inLanguage":"nb-NO","@id":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#primaryimage","url":"https:\/\/www.pvb.com\/wp-content\/uploads\/2022\/06\/22.6.15.webp","contentUrl":"https:\/\/www.pvb.com\/wp-content\/uploads\/2022\/06\/22.6.15.webp","width":1280,"height":720,"caption":"Fire Safety Hazard"},{"@type":"BreadcrumbList","@id":"https:\/\/www.pvb.com\/news\/distributed-pv-power-station-dc-arc-and-fire-safety-hazard-application-scenario-risk-analysis\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.pvb.com\/"},{"@type":"ListItem","position":2,"name":"Distributed PV power station DC arc and fire \u201csafety\u201d hazard \u2013 application scenario risk analysis"}]},{"@type":"WebSite","@id":"https:\/\/www.pvb.com\/#website","url":"https:\/\/www.pvb.com\/","name":"PVB Energilagring","description":"PV Batteril\u00f8sninger","publisher":{"@id":"https:\/\/www.pvb.com\/#organization"},"alternateName":"PVB","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.pvb.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nb-NO"},{"@type":"Organization","@id":"https:\/\/www.pvb.com\/#organization","name":"PVB Energilagring","url":"https:\/\/www.pvb.com\/","logo":{"@type":"ImageObject","inLanguage":"nb-NO","@id":"https:\/\/www.pvb.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.pvb.com\/wp-content\/uploads\/2023\/10\/20251218-144542.png","contentUrl":"https:\/\/www.pvb.com\/wp-content\/uploads\/2023\/10\/20251218-144542.png","width":826,"height":800,"caption":"PVB Energy Storage"},"image":{"@id":"https:\/\/www.pvb.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/pvbmicropowerhub","https:\/\/x.com\/PVB_PowerVault"],"alternateName":["PVB"],"parentOrganization":{"@type":"Organization","@id":"https:\/\/www.beny.com\/#organization","name":"BENY New Energy","url":"https:\/\/www.beny.com\/"}},{"@type":"Person","@id":"https:\/\/www.pvb.com\/#\/schema\/person\/9e2e81b5f4240256ac8618c6f5aed1d2","name":"PVB Energilagring","image":{"@type":"ImageObject","inLanguage":"nb-NO","@id":"https:\/\/www.pvb.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/22d020bc1b45981d5477872a66ace2a1258a147e929471f93f367387d7c67855?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/22d020bc1b45981d5477872a66ace2a1258a147e929471f93f367387d7c67855?s=96&d=mm&r=g","caption":"PVB Energy Storage"}}]}},"_links":{"self":[{"href":"https:\/\/www.pvb.com\/no\/wp-json\/wp\/v2\/posts\/7044","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pvb.com\/no\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pvb.com\/no\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pvb.com\/no\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pvb.com\/no\/wp-json\/wp\/v2\/comments?post=7044"}],"version-history":[{"count":4,"href":"https:\/\/www.pvb.com\/no\/wp-json\/wp\/v2\/posts\/7044\/revisions"}],"predecessor-version":[{"id":7534,"href":"https:\/\/www.pvb.com\/no\/wp-json\/wp\/v2\/posts\/7044\/revisions\/7534"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.pvb.com\/no\/wp-json\/wp\/v2\/media\/18378"}],"wp:attachment":[{"href":"https:\/\/www.pvb.com\/no\/wp-json\/wp\/v2\/media?parent=7044"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pvb.com\/no\/wp-json\/wp\/v2\/categories?post=7044"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pvb.com\/no\/wp-json\/wp\/v2\/tags?post=7044"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}